Neutral Arm Assembly
EARLY MODELS
7
23
24
1. Philips head screw
2. Flat washer
3. Micro switch
4. Keps nut
5. Neutral bracket
6. Flange nut
7. Flange head nut
8. Neutral arm
9. Flange bushing
10. Thrust washer
o
11. 90
grease fitting
12. Lock nut
Piston Pump Removal (Fig. 62)
1. Remove traction belt from the pulley (see Replace
Traction Belt).
2. Remove pulley from the taper lock bushing:
A. Remove cap screws securing pulley to the taper
lock bushing.
IMPORTANT: Excessive or unequal pressure on the
cap screws can break the bushing flange.
B. Insert cap screws into threaded removal holes of
the pulley. Tighten screws progressively and evenly
until the pulley is loose on the bushing. Remove
pulley from the bushing.
Reelmaster 3100−D
30
22
4
9
12
8
31
11
18
9
14
12
15
26
Figure 63
13. Spacer
14. Traction stud
15. Traction control cable
16. Isolator stud
17. Flat washer
18. Extension spring
19. Cap screw
20. Flat washer
21. Pump lever
22. Flange nut
23. Flange head screw
24. Cable support bracket
Page 4 − 97
5
6
7
3
32
2
1
10
29
20
17
27
19
16
33 34
25. Ball bearing
26. Rod end
27. Lock nut
28. Screw
29. Cap screw
30. Pump mount plate
31. Spring dampener
32. Adjuster bracket
33. Flat washer
34. Isolation mount
35. Lock nut
36. Piston pump
CAUTION
The extension spring is under tension and may
cause personal injury during removal. Use cau-
tion when removing spring from the pump lever.
3. Remove neutral arm assembly from the piston pump
as follows (Figs. 63 and 64):
A. Disconnect electrical connector from the micro
switch (early models).
B. Remove extension spring from the cable support
bracket and pump lever.
36
21
34 33
13
35
25
28
Hydraulic System