Component Testing; Ignition Switch - Toro Reelmaster 3100-D Service Manual

Hide thumbs Also See for Reelmaster 3100-D:
Table of Contents

Advertisement

Component Testing

For accurate resistance and/or continuity checks, elec-
trically disconnect the component being tested from the
circuit (e.g. unplug the ignition switch connector before
doing a continuity check).
NOTE: For more component testing information, see
the Kubota Workshop Manual, Diesel Engine, 05 Se-
ries.

Ignition Switch

The ignition (key) switch has three positions (OFF, RUN,
and START). The terminals are marked as shown. The
circuitry of the ignition switch is shown in the chart. With
the use of a multimeter (ohms setting), the switch func-
tions may be tested to determine whether continuity ex-
ists between the various terminals for each position.
Verify continuity between switch terminals.
SWITCH
NORMAL
POSITION
CIRCUITS
OFF
RUN
START
Electrical Systems
OTHER
CIRCUITS
NONE
NONE
B + A + I
X + Y
B + S + I
NONE
When testing electrical components for continu-
ity with a multimeter (ohms setting), make sure
that power to the circuit has been disconnected.
B
1
1. Switch
2. Key
Page 5 − 30
CAUTION
A
Y
S
I
X
Figure 3
3
4
Figure 4
3. Hex nut
4. Lock washer
OFF
45 °
Figure 5
Reelmaster 3100−D
2
RUN
45 °
START