4.2.8.8 Pump Phase Sensor
1. Remove "Pump Unit".
(Refer to "4.2.8.6 Box Assy., Flushing / Pump Unit" (p316).)
2. Remove the two screws securing the "Pump Cover".
(Refer to Figure 4-163.)
C.B.P. 3x8:
2 pcs.
3. Remove the "Pump Cover" in the direction of the arrows.
(Refer to Figure 4-164.)
Disassembly & Assembly
Figure 4-163. Screws Securing the Pump Cover
Disassembly Procedures
C.B.P. 3x8
2
1
Figure 4-164. Pump Cover Removal