4. Peel off the acetate tape attached to the gap between the "Frame, Fan,
Unit" and the main unit.
5. Remove the two screws securing "Frame, Fan, Unit" and remove "Frame,
Fan, Unit" by pulling it toward you.
C.B.S. 3x6:
2 pcs.
Align the two main frame dowels with the two positioning
holes on the "Frame, Fan, Unit".
Disassembly & Assembly
(Refer to Figure 4-53.)
Disassembly Procedures
Frame, Fan, Unit
Dowel and Positioning Hole
Dowel and Positioning Hole
C.B.S. 3X6
Figure 4-53. Frame, Fan, Unit Removal
Revision C
Acetate Tape
Dowel and Positioning Hole
C.B.S. 3X6
245