"Lever, Inclination" Removal; Removal Of Screw Securing Head Unit; Head Unit Removal - Epson Stylus Pro 4400 Service Manual

Hide thumbs Also See for Stylus Pro 4400:
Table of Contents

Advertisement

EPSON Stylus Pro 4400/4450/4800/4880/4880C
5. Remove the "Tension Spring, 3.81" from the hooks of both the "Head Unit"
and the "Lever, Inclination".
(Refer to Figure 4-79.)
6. Remove the three screws and the washer that secure the "Lever,
Inclination" to the "Carriage Unit to remove the "Lever, Inclination".
(Refer to Figure 4-79.)
C.B.P. (P2) 3x12:
C.B.P. 3x8 (+washer 3.0x0.5x8):1 pc.
7. Remove the screw securing the "Head Unit" to the "Carriage Unit".
(Refer to Figure 4-80.)
C.B.P. (P2) 3x12:
8. Release the harness from the tab shown in
"Carriage Unit" toward you.
9. Lift the "Head Unit" together with the "Ink Tube Unit" to remove from
the"CarriageUnit".
(Refer to Figure 4-81.)
Extension Spring, 3.81
C.B.P. (P2) 3x12
C
Lever, Inclination
Figure 4-79. "Lever, Inclination" Removal
Disassembly & Assembly
2 pcs.
1 pc.
Figure
4-80, and move the
B
C.B.P. 3x8
+washer 3.0x0.5x8
Disassembly Procedures
When installing the "Lever, Inclination", follow the steps
below.
1. Tighten the Screw A.
2. Attach the "Extension Spring, 3.81".
3. Tighten the Screw C first and then the Screw B.
C.B.P. (P2) 3x12
Figure 4-80. Removal of Screw Securing Head Unit
A
Tab
Figure 4-81. Head Unit Removal
Revision C
Head Unit
268