(c) When actions are set for a job
When actions are set for a job, if a communication error occurs, a timeout time will be generated.
In the case of multiple action settings, timeout time is generated for each action.
For the timeout time, refer to the following.
7.5 Setting Items of DB Connection Service Setting Tool
Program execution (before actions)
Action 1
Action 2
Action 10
Program execution (after actions)
The time taken until completion of the job is obtained from the formula shown below.
No. of communications
No. of communications: Total number of set communication actions and program executions
Example) Time taken until completion of a job in the event of a communication error
No. of communications: 10 + 1 + 1 = 12
Time taken until job completion: 12
Communication action
Program execution (before action)
Program execution (after action)
Timeout
(d) Monitoring interval timeout
Depending on the number of set jobs or the trigger condition setting, the monitoring interval timeout may be
generated.
Appendix2 About Monitoring Interval Timeout
Job execution
Timeout time occurs for each.
Timeout time
30s = 360s
Item
Setting
12
1
1
30 seconds
5 - 25