(b) When manual resend is selected for the job
1.
If SQL texts cannot be sent to the database due to network disconnection or failure of the database
server computer or database software, the system starts DB buffering after detection of a timeout.
2.
After started, DB buffering is performed without checking whether SQL texts can be sent to the
database or not for each job activation.
3.
The data stored in the DB buffer are resend when manual resend is executed.
(8) Precaution on the
Do not remove the CF card from the GOT during DB buffering.
5 - 22
5.1 DB Interface Function
Job startup
After sending
SQL texts,
timeout detected
DB buffering executed
DB buffering
Recovery from network
disconnection
Job startup
DB buffering executed
Manual resend operation
Resending DB buffer data