(4) Check return value
(a) Set whether to check the return value or not.
When the [Check return value] box is checked, the return value (End code) of the executed program is
checked.
If no return value is returned within the [DB access timeout] time set in DB Connection Service Setting Tool,
a timeout error is detected and the job execution is canceled.
For [DB access timeout], refer to the following:
7.5 Setting Items of DB Connection Service Setting Tool
(b) When [Check return value] is selected, set the following items.
1) Normal return value (Default: 0)
Set a normal return value.
2) Write the value into the tag when the value is faulty.
When the [Write the value into the tag when the value is faulty] box is checked, if the return value is not
normal, a value is assigned to the specified tag component.
Set a tag component to which a value is assigned when this is selected.
• Tag, Component
Select a tag component to which a value is assigned.
Tags that have a tag component with [Array setting] cannot be selected.
• Substitute value
Directly enter a substitute value.
3) Do not execute job when the value is faulty. ([Program execution setting (before action)] only)
When the [Do not execute job when the value is faulty] box is checked, if the return value is faulty, the
job execution is canceled.
(5) Wait for execution completion
If the [Wait for execution completion] box is checked, the next processing is executed after completion of the
program execution.
When [Check return value] is selected, [Wait for execution completion] is always selected.