(2) Access log of DB Connection Service
Error code
0x20100001
0x20100002
0x20100011
0x20100012
0x20200001
0x20200002
0x20300001
0x20300010
0x20300011
0x20300012
0x20300013
0x20300014
0x20300015
8 - 14
8.2 Error Code List
Error description and cause
(Service Not Start.)
Failed to start the service due to insufficient memory.
(Service Not Start.)
Failed to start the service due to insufficient resources.
(Service Not Start.)
Failed to start the service due to failure of the server port
initialization.
(Service Not Start.)
Another application has opened the server port.
(Not Initialize a service for each client: [IP address])
Failed to initialize a service for each client due to
insufficient memory.
(Deny network connection request from [IP address])
Rejected the connection request from the non-permitted
IP address.
(SID [Session ID]: Request Receive Error: [IP address])
Failed to receive data due to insufficient memory.
(SID [Session ID]: Request Receive Error: [IP address])
Connection disconnected during request reception.
(SID [Session ID]: Request Receive Error: [IP address])
Timed out during request reception.
(SID [Session ID]: Request Receive Error: [IP address])
Detected failure of the MES interface module while
waiting for or receiving a request.
(SID [Session ID]: Request Receive Error: [IP address])
Receive I/O error
(SID [Session ID]: Request Receive Error: [IP address])
Buffer overrun (Request length exceeded)
(SID [Session ID]: Request Receive Error: [IP address])
Received an invalid request.
Corrective action
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
• If a firewall software has been installed, make the
specified server port operational.
• Terminate the application that has opened the server
port.
• Set another server port No. with DB Connection
Service Setting Tool.
7.5 Setting Items of DB Connection Service
Setting Tool
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
• Using DB Connection Service Setting Tool, add the IP
address to those with connection permission.
7.5 Setting Items of DB Connection Service
Setting Tool
• Terminate any unnecessary applications.
• Add more memory to the personal computer.
• Check if it is connected to the network.
• Check if the gateway and/or hub is operating.
• Check if the power of the GOT has not been turned off.
• Check the source IP address setting.
• Confirm the version of the Option OS (MES Interface).