Message
Message
Stopped: Seat switch fault
Fault
/ Check to see if seat is
plugged in / Restart, if
problem persists contact
service
Stopped: Seat switch fault
Fault
/ Check to see if seat is
plugged in / Restart, if
problem persists contact
service
Blades Off: PTO switch
Fault
fault / Restart, if problem
persists contact service
Stopped: Brake sensor
Fault
fault/ Restart, if problem
persists contact service
Mower's action
type
Disables Blades and Drive
Disables Blades and Drive
Disables Blades
Disables Blades and Drive
Code
number
Trigger
(engineering
screen)**
Interlock1
Dual seat switch inputs
code 8
are not equal
code 16
code 24
Interlock1
Detected one or more
code 8
motors not slowing down
after seat switch opened
Interlock 2
Dual PTO switches not
code 1
matched
Brake sensor rises to or
near 5v
Possible causes
Poor connection, faulty
switch, damaged harness
Poor connection, faulty
switch, damaged harness
Faulty brake switch, poor
connection or a damaged
harness