Cub Cadet RZT-S Zero Shop Manual page 108

Hide thumbs Also See for RZT-S Zero:
Table of Contents

Advertisement

Message
Message
Blades off: Right deck fault
Fault
Restart, if problem per-
sists contact service
Overload: Slow down or
Fault
raise deck
Stopped: Drive sensor
Fault
fault / Restart, if problem
persists contact service
Stopped: Drive sensor
Fault
fault / Restart, if problem
persists contact service
Stopped: Drive sensor
Fault
fault / Restart, if problem
persists contact service
Stopped: Drive sensor
Fault
fault / Restart, if problem
persists contact service
Stopped: Over-voltage /
Fault
Restart, if problem persists
contact service
Mower's action
type
Disables Blades
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Code
number
Trigger
(engineering
screen)**
16384
POST dynamic gating test
32768
Instantaneous under volt-
age
Interlock 1
Dual Throttle Input Signals
code 1
differ by more than
allowed tolerance
Interlock 1
CRC check off throttle cali-
code 2
bration parameters has
failed
Interlock 1
Throttle not in neutral
code 4
when trying to close main
contactor
Corrupt calibration param-
eters and VCM doesn't
know which throttle input
signal to use.
Controller voltages greater
than 59V for more than 5
continuous seconds.
Possible causes
Controller failure
Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts
Poor connection, faulty
switch, damaged harness
TPS needs to be re-cali-
brated
Drive pedal being acti-
vated, calibration error
TPS needs to be re-cali-
brated
Batteries over charged

Hide quick links: