Cub Cadet RZT-S Zero Shop Manual page 101

Hide thumbs Also See for RZT-S Zero:
Table of Contents

Advertisement

Message
Message
Blades off: Left Deck Fault
Operator error
Blades off: Right Deck
Fault
Blades off: Left Deck Fault
Operator error
Blades off: Right Deck
Fault
Stopped: Left hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Left hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Left hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Left hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Left hub fault /
Fault
Restart, if problem persists
contact service
Mower's action
type
Disables Blades
Disables Blades
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Code
number
Trigger
(engineering
screen)**
2
One or both of the deck
motors are pulling 110
amps or more
16
One or both of the deck
controllers are at 100
or more
1
Controller over voltage
2
Phase over current
4
Current sensor calibration
8
Not used
16
Controller temperature is
o
over 100
C
Possible causes
Too much material being
cut, build up of clippings
under the deck, binding of
the motor, faulty motor or
a faulty controller
Too much material being
o
cut, build up of clippings
C
under the deck, binding of
the motor, faulty motor or
a faulty controller
Batteries over charged,
usually from regen. brak-
ing
Motor pulling too much
current, short bursts
Internal controller issue
Controller overheating
from the motor pulling too
much current, usually from
being overloaded, faulty
controller

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents