Cub Cadet RZT-S Zero Shop Manual page 106

Hide thumbs Also See for RZT-S Zero:
Table of Contents

Advertisement

Message
Message
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Left deck fault
Fault
Restart, if problem per-
sists contact service
Overload: Slow down or
Fault
raise deck
Blades off: Right deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Right deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Right deck fault
Fault
Restart, if problem per-
sists contact service
Blades off: Right deck fault
Fault
Restart, if problem per-
sists contact service
Mower's action
type
Disables Blades
Disables Blades
Disables Blades
Disables Blades
Disables Blades and Drive
Disables Blades
Disables Blades
Disables Blades
Disables Blades
Code
number
Trigger
(engineering
screen)**
2048
Throttle voltage outside
range
4096
Instantaneous controller
over voltage
8192
Internal error
16384
POST dynamic gating test
32768
Instantaneous under volt-
age
1
Controller over voltage
2
Phase over current
4
Current sensor calibration
8
Not used
Possible causes
N/A
Batteries over charged,
usually from regen. brak-
ing
Controller failure
Controller failure
Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts
Batteries over charged,
usually from regen. brak-
ing
Motor pulling too much
current, short bursts
Internal controller issue

Hide quick links: