Message
Message
Overload: Slow down or
Fault
raise deck
Stopped: Right hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Right hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Right hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Right hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Right hub fault /
Fault
Restart, if problem persists
contact service
Stopped: Right hub fault /
Fault
Restart, if problem persists
contact service
Overload: Slow down or
Fault
raise deck
Mower's action
type
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Code
number
Trigger
(engineering
screen)**
32768
Instantaneous under volt-
age
1
Controller over voltage
2
Phase over current
4
Current sensor calibration
8
Not used
16
Controller temperature is
o
over 100
C
32
Motor hall sensor fault
64
Controller under voltage
Possible causes
Momentary drop in bat-
tery voltage from the
motor pulling too much
current, short bursts
Batteries over charged,
usually from regen. brak-
ing
Motor pulling too much
current, short bursts
Internal controller issue
Controller overheating
from the motor pulling too
much current, usually from
being overloaded, faulty
controller
Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor
Battery voltage too low,
poor connection, corrosion