Cub Cadet RZT-S Zero Shop Manual page 102

Hide thumbs Also See for RZT-S Zero:
Table of Contents

Advertisement

Message
Message
Stopped: Left hub fault /
Fault
Restart, if problem persists
contact service
Overload: Slow down or
Fault
raise deck
Stopped: Left hub fault /
Fault
Restart, if problem per-
sists contact service
Stopped: Left hub fault /
Fault
Restart, if problem per-
sists contact service
Stopped: Left hub fault /
Fault
Restart, if problem per-
sists contact service
Stopped: Left hub fault /
Fault
Restart, if problem per-
sists contact service
Stopped: Left hub fault /
Fault
Restart, if problem per-
sists contact service
Stopped: Left hub fault /
Fault
Restart, if problem per-
sists contact service
Stopped: Left hub fault /
Fault
Restart, if problem per-
sists contact service
Mower's action
type
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Code
number
Trigger
(engineering
screen)**
32
Motor hall sensor fault
64
Controller under voltage
128
POST static gating test
512
Instantaneous phase over
current
1024
Motor has reached at tem-
perature of 105
2048
Throttle voltage outside
range
4096
Instantaneous controller
over voltage
8192
Internal error
16384
POST dynamic gating test
Possible causes
Disconnected harness
connector, damaged har-
ness, corrosion, faulty
motor
Battery voltage too low,
poor connection, corrosion
Controller failure
Motor pulling too much
current, short bursts
Motor over loaded, faulty
o
C
N/A
Batteries over charged,
usually from regen. brak-
ing
Controller failure
Controller failure

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents