Message
Stopped: Steering sensor
Fault
fault / Restart, if problem
persists contact service
Stopped: Pre-charge fail-
Fault
ure / Restart, if problem
persists contact service
Stopped: Left deck comm
Fault
fault / Restart, if problem
persists contact service
Stopped: Right deck
Fault
comm fault / Restart, if
problem persists contact
service
Stopped: Left wheel comm
Fault
fault / Restart, if problem
persists contact service
Mower's action
type
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Disables Blades and Drive
Code
number
Trigger
(engineering
screen)**
Steering signal drops to or
near 0V, or rises to or near
5V.
After pressing and holding
the Start button for 10 sec-
onds, some or all of the
drive controllers have not
reached a bus voltage of
within 4 volts of the battery
voltage.
Interlock1
Network communications
code 32
timeout
Interlock1
Network communications
code 32
timeout
256 (or no code
Network communications
if VCM timed
timeout
out and is not
able to read a
fault code from
the controller.)
Possible causes
Faulty steering sensor,
calibration error, move-
ment between the yoke
and the axle casting, sen-
sor not parallel to the mag-
net, magnet not properly
centered, poor connection,
faulty switch, or a dam-
aged harness
Poor connection, faulty
controller
Disconnected harness
connector, damaged har-
ness, corrosion
Disconnected harness
connector, damaged har-
ness, corrosion
Disconnected harness
connector, damaged har-
ness, corrosion