Cisco Prisma II Installation And Operation Manual page 77

Optical amplifiers
Hide thumbs Also See for Prisma II:
Table of Contents

Advertisement

Boot Dialog for ICIM/SNMP Configuration,
The boot dialog's primary use is to flash a new version of the ICIM application via a
TFTP server.
Important: Do this only under the direction of Cisco.
During a flash operation, the low-level parameters can be changed, including
community strings, port number for traps, IP address, etc.
The procedures below initially tells the ICIM that it is to be updated (flashed),
whereupon it presents a configuration dialog, new values are entered and saved,
then the ICIM is told to not update the program and proceed to normal ICIM
operations.
Preparing to Change Parameters
Follow these steps to prepare to change parameters.
1.
When the ICIM is powered up, it presents a summary screen along with a
prompt to "...press any key within 5 seconds."
Result: The following screen appears.
Start-Up Configuration Dialog
--------------------------------------------------------------------
START-UP MODE:
Run ICIM Application
NETWORK INTERFACE PARAMETERS:
IP address on LAN is 192.133.194.219
LAN interface's subnet mask is 0xffffff00
SNMPv1 COMMUNITY:
Read Community: public
Trap Community: SNMP_trap
HARDWARE PARAMETERS:
Serial channels will use a baud rate of 9600
Board's Serial Number is ^AAIIJHC
HARDWARE PARAMETERS:
ICIM BSP Revision: ICIM Boot Rom, Rev: BT 0204 (02-23-2004)
MPC860 (Rev 0.2) CPU running at 49 Mhz with 5 Mhz input clock
ICIM Board with 16 Mbytes DRAM and 4 Mbytes App FLASH and 2 Mbytes
Boot FLASH
This board's Ethernet hardware address is 0:2:DE:1:2:3
BOOT ROM PARAMETERS:
IP address of the TFTP host is 192.133.194.4
The file to download and start is ram.crc
After board is reset, start-up code will wait 5 seconds
-------------------------------------------------------------
To change any of this, press any key within 5 seconds
Note: During the first couple of seconds, the ICIM does not respond to a key
press.
78-739260-01 Rev F
Continued
Write Community: private
Trap Port: 162
Operation Using the ICIM