Checking Optical Amplifier Alarms Using the ICIM,
Setting Adjustable Alarm Thresholds
Follow these steps to change an adjustable alarm threshold from the factory default.
1.
At the MODULE menu, press the
Result: The STATUS menu appears on the ICIM.
2.
Press the
n/a appears, you cannot configure that alarm threshold. Press the
highlight the next parameter's alarm threshold.
3.
When the threshold that you wish to set is highlighted, press the
4.
Press the
5.
Press the
Note: Press the Cancel (
6.
Press the
Result: Data Saved appears.
7.
When finished, press the
Optical Amplifier Alarm Threshold Menus
Some typical alarm threshold menus are shown below. Exact values are dependant
on amplifier type and configuration.
S T A T U S
- - - - - - - - - -
S h e l f
S l o t
- - - - - - - - - -
1 5 5 0 n m
O p t i c a l
A m p l i f i e r
- - - - - - - - - -
L a s B i a s
M a j H 0 . 3 4 9
M i n H 0 . 3 4 0
M i n L - 1 . 6 5 0
M a j L - 0 . 6 5 0
78-739260-01 Rev F
key. The alarm thresholds previously set appear. If the label
SEL
key or the
key to change the increment size.
key or the
ALRM
)key to return to the previous menu.
key to save the changes.
ENTER
MAIN
key to return to the MAIN menu.
S T A T U S
- - - - - - - - - -
0
S h e l f
6
S l o t
- - - - - - - - - -
1 5 5 0 n m
O p t i c a l
A m p l i f i e r
- - - - - - - - - -
O u t P w r
M a j H 1 7 . 0 0
M i n H 1 6 . 7 0
M i n L 1 5 . 3 0
M a j L 1 5 . 0 0
Operation Using the ICIM
Continued
key.
STAT
key to adjust the alarm threshold.
S T A T U S
- - - - - - - - - -
0
S h e l f
6
S l o t
- - - - - - - - - -
1 5 5 0 n m
O p t i c a l
A m p l i f i e r
- - - - - - - - - -
I n P w r
M a j H 5 0 . 0 0
M i n H 2 5 . 7 0
M i n L 0
M a j L - 1 0 . 0 0
key to
key.
ENTER
0
6
3-23