Table 6-1 Type Options For Show Logging Onboard Command - Cisco 12000 - Series Chassis Modular Expansion Base Hardware Installation Manual

Router sip and spa
Hide thumbs Also See for 12000 - Series Chassis Modular Expansion Base:
Table of Contents

Advertisement

Advanced SIP Troubleshooting
Router# show logging onboard
MAIN: 800-2427-03 rev A0, S/N CAB0549LRMK
Cumulative runtime: 20h 00m (inexact)
Use the show logging onboard command to list information about a specific parameter. Type options
are shown in
Table 6-1
Type
boot
clear
crash
environment
mem-errors
runtime
Example output of the show logging onboard command follows:
RouterA# show logging onboard slot 2 boot
Boot location #0: slot 8 in 'Test_1'
Location #0 runtime: 13 weeks 13h 00m (inexact)
Boot location #1: slot 2 in 'Test_2'
Temperature after last boot in location #0: inlet 30 C, hotpoint 39 C
Temperature after last boot in location #0: inlet 31 C, hotpoint 40 C
show diag slot Output
Router# show diag 1
SLOT 1 (RP/LC 1 ): 3 Port Gigabit Ethernet
MAIN: type 68, 800.6376.01 rev E0 dev 0
HW config: 0x00 SW key: 00.00.00
PCA: 73.4775.02 rev E0 ver 2
HW version 2.0 S/N CAB0450G8FX
MBUS: Embedded Agent
Test hist: 0x00 RMA#: 00.00.00 RMA hist: 0x00
DIAG: Test count: 0x00000001 Test results: 0x00000000
FRU: Linecard/Module: 3GE.GBIC.SC=
Route Memory: MEM.GRP/LC.64=
Packet Memory: MEM.LC1.PKT.256=
L3 Engine: 2 . Backbone OC48 (2.5 Gbps)
MBUS Agent Software version 01.46 (RAM) (ROM version is 02.10)
Using CAN Bus A
ROM Monitor version 10.06
Fabric Downloader version used 05.01 (ROM version is 05.01)
Primary clock is CSC 0 Board is analyzed
Board State is Line Card Enabled (IOS RUN )
Insertion time: 00:00:10 (5d16h ago)
DRAM size: 67108864 bytes
FrFab SDRAM size: 134217728 bytes, SDRAM pagesize: 8192 bytes
ToFab SDRAM size: 134217728 bytes, SDRAM pagesize: 8192 bytes
1 crash since restart
Cisco 12000 Series Router SIP and SPA Hardware Installation Guide
6-4
Table
6-1.
Type Options for show logging onboard Command
Description
Boot record
Clear record
Crash record
Environmental error record
Memory error record
Runtime count
Chapter 6