Cisco Catalyst 8300 Series Hardware Installation Manual
Cisco Catalyst 8300 Series Hardware Installation Manual

Cisco Catalyst 8300 Series Hardware Installation Manual

Edge ucpe
Hide thumbs Also See for Catalyst 8300 Series:

Advertisement

Quick Links

Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide
First Published: 2023-01-23
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Catalyst 8300 Series

  • Page 1 Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide First Published: 2023-01-23 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 © 2024 Cisco Systems, Inc. All rights reserved.
  • Page 3: Table Of Contents

    C H A P T E R 1 Overview of Cisco Catalyst 8300 Series Edge uCPE Cisco Catalyst 8300 Series Edge uCPE Chassis Location of Labels on Cisco Catalyst 8300 Series Edge uCPE Hardware Features Status Indicators and LEDs for Gigabit Ethernet Ports...
  • Page 4 Installing and Removing a Network Interface Module (NIM) Installing Pluggable Interface Module Installing Drive Bays Replace (Remove and Install) Fan Tray Remove Small Form Pluggable Modules C H A P T E R 5 Laser Safety Guidelines Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 5: Overview Of Cisco Catalyst 8300 Series Edge Ucpe

    Overview of Cisco Catalyst 8300 Series Edge uCPE The Cisco Catalyst 8300 Series Edge universal Customer Premises Equipment (uCPE) is a purpose-built x86 platform that is designed for branch virtualization. It enables device consolidation across network and security functions, improves operational flexibility and service agility, simplifies network operations, and results in reduced deployment times and fewer truck rolls for delivery of add-on services.
  • Page 6 M.2 disk slot (75 GB USB M.2, 600 GB or 2 TB NVMe disk) Figure 2: Chassis- Bezel Side PSU Slot GND lug or ground point Fan tray (Visible through chassis) Chassis on/off switch PSU slot Figure 3: Chassis- Internal DIMM slots x 4 Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 7: Location Of Labels On Cisco Catalyst 8300 Series Edge Ucpe

    Location of Labels on Cisco Catalyst 8300 Series Edge uCPE The figure below shows the location of the labels on the Cisco Catalyst 8300 Series Edge uCPE. Labels are located at the same location on all the Cisco Catalyst 8300 Series Edge uCPE.
  • Page 8: Hardware Features

    GHz and maximum turbo frequency of 3.1 GHz. • Dual In-Line Memory Modules (DIMMs): Stores the running configuration and routing tables and is used for packet buffering by the network interfaces. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 9: Status Indicators And Leds For Gigabit Ethernet Ports

    NIM, E1.S, M.2 and U.2) that do not have a functional module installed. Status Indicators and LEDs for Gigabit Ethernet Ports The front panel Gigabit Ethernet ports have eight ports: four RJ45 ports and four SFP ports. Figure 6: Status and LED indicators Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 10 SFP+ port 0/1/2/3 Link LED Off: not present or not configured, Yellow: Loss of Signal, Green: Link established BMC Management port Activity Green BMC Management Ethernet Activity LED Off: No activity, blinking Green: Activity Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 11 Green- All temperature sensors and fans in the system are within acceptable range. Beacon (1 LED) B LED4 Beacon LED Off- Default state Blue- The administrator can light to show the router needs attention Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 12: Fans, Ventilation, And Airflow

    Under all conditions, the fans operate at the slowest speed possible to conserve power and reduce noise. When necessary, the fans operate at higher speeds for different environmental conditions. Figure 8: Airflow direction from front to back Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 13: Prepare For Installation

    SAVE THESE INSTRUCTIONS Warning Statement 1074 Comply with Local and National Electrical Codes To reduce risk of electric shock or fire, installation of the equipment must comply with local and national electrical codes. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 14: Network Equipment-Building System (Nebs) Statements

    United States. It is not a legal or regulatory requirement, but rather an industry requirement. The following NEBS statements apply to the Cisco Catalyst Edge uCPE 8300: Warning Statement 7003—Shielded Cable Requirements for Intrabuilding Lightning Surge The intrabuilding port(s) of the equipment or subassembly must use shielded intrabuilding cabling/wiring that is grounded at both ends.
  • Page 15: General Safety Guidelines For Electrical Equipment

    • Do not work alone if hazardous conditions exist. • Never assume that power is disconnected from a circuit. Always check. • Never open the enclosure of the internal power supply. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 16: Site Requirements

    Be sure that nothing else rests on your system component cables or power cable. • If you turn off your system, wait at least 30 seconds before turning it on again to avoid system component damage. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 17: Mounting Requirements

    Weight 19 lb (9.015 kg) when fully configured You can mount the Cisco Catalyst 8300 Edge uCPE using the following ways: • On a desktop • In a rack or cabinet (optional 4-point kit to use if rear support is required) •...
  • Page 18: Network Cabling Specification

    • Screws that fit your rack • Wire crimper for chassis grounding - to be used along with the ground lug kit • One 14 AWG cable for the ground lug kit Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 19 • Cables for connection to the WAN and LAN ports (depending on the configuration) Note If you order the required cables when you purchase the device, the cables ship along with the product. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 20 Prepare for Installation Required Tools and Equipment Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 21: Install The Cisco Catalyst 8300 Series Edge Ucpe

    If not already installed, the DIMMs must be installed before rack-mounting the chassis. Desktop-Mounting the Chassis The Cisco Catalyst 8300 Edge uCPE has circular markings on the bottom of the chassis for rubber feet. Apply the rubber feet when installing the router on horizontal surface (desk or shelf).
  • Page 22 Circular markings for placing the feet Rack-Mounting the Chassis The Cisco Catalyst 8300 Edge uCPE can be installed in 19-inch (48.26-cm) or 23-inch (58.42-cm) racks. The mounting ears for the device are designed for #12 screws for securing to the rack.
  • Page 23 RFID is provisioned. The following image shows the brackets secured to the I/O-face in the recessed position (RFID is applied). If flush securing is desired, slide the bracket forward and secure the other 4 bracket-securing holes. Note Recessed mounting is not supported on the PSU-face. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 24 Install the Cisco Catalyst 8300 Series Edge uCPE Installing the Cisco Catalyst 8300 Series Edge uCPE Figure 11: Rack mount brackets applied recessed from I/O-face RFID provisioned (reference) Rack-mount bracket Screws Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 25 If the small holes do not line up with the rack holes, raise or lower the brackets to the next rack hole. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 26 3. Secure the device using mounting screws appropriate for your equipment frame. The rack mount brackets have been designed for #12 screws. 4. Tighten the screws to the appropriate torque value for your equipment. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 27 Installing the Cisco Catalyst 8300 Series Edge uCPE Figure 13: Mounting the Chassis on the Rack- Front (I/O face) Shown for 19 inches Rack Mount Securing screws (not included) 19-inch rack (upright) Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 28 Four-point Mounting in a Cabinet Four-point mounting is supported for 19-inches cabinets that require rear-support of the device. A range of rear-support depths is supported depending on whether you choose flush-mounting or recessed-mounting. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 29 Installing the Cisco Catalyst 8300 Series Edge uCPE Figure 15: Four-point kit assembly for 19-inches cabinets (recessed-mounting shown) 19-inches rackmount brackets Securing screws Slider bracket Rear bracket (adjustable depth) RFID (reference) Figure 16: Flush Mount (No RFID) Depths Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 30 1. Attach the brackets to the device using the screws provided with the mounting kit. Two screws should be used to attach each bracket to the chassis as shown in the following figure. Note The wall-mounting kit is different from the rack-mounting kit. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 31 Route the cables so that they do not put a strain on the connectors or mounting hardware. For safety reasons, the chassis may only be mounted with ports going out in left or right direction. Do not mount the chassis with ports facing upward or downward direction. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 32: Grounding The Chassis

    To reduce risk of electric shock, when installing or replacing the unit, the ground connection must always be made first and disconnected last. If your unit has modules, secure them with the provided screws. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 33: Initial Server Setup

    • When you see the prompt, you can press F2 to get into the setup (BIOS) to change some settings. • After you have performed the required configuration, save the setup and continue to boot. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 34 Install the Cisco Catalyst 8300 Series Edge uCPE Initial Server Setup For more information on initial server setup see, Hardware Installation Guide for Cisco Catalyst 8300 Series Edge uCPE. Remote Connection Procedure • Plug in your terminal server to the Serial port (Refer to front panel of chassis).
  • Page 35: Install And Upgrade Field Replaceable Units

    2. Place the chassis on a flat surface. 3. Remove the screws from the top of the chassis cover. 4. Remove screws from each side and from the top of the device as shown in the figure. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 36: Instal A Dual In-Line Memory Module (Dimm)

    2. Locate the DIMM slots on the device. There are four DIMM slots in the chassis and you can install the DIMM module on any of the slots. 3. Make sure that both latches on the DIMM connector are in the open position. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 37: Removing A Dimm

    3. Pull the latches away from the DIMM at both ends to lift the DIMM slightly. Pull the DIMM out of the socket. 4. Place the DIMM in an antistatic bag to protect it from ESD damage. 5. Replace the chassis cover. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 38: Installing The M.2 Storage Module

    Note The disk used in M.2 is also the boot disk. If you replace the M.2 disk, you must reinstall Cisco NFVIS operating system once again. 4. Plug in the new M.2 storage module in the same location and secure it with the screws.
  • Page 39: Installing And Removing A Network Interface Module (Nim)

    1. Locate the NIM slot on the front panel. 2. Loosen the screws to remove NIM blank cover. 3. Insert the NIM into the slot. 4. Tighten the screws to secure the NIM in the slot. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 40: Installing Pluggable Interface Module

    Installing Pluggable Interface Module To insert the PIM into the router, do these steps: 1. Insert and then gently push the PIM into the pluggable slot until firmly seated in the slot. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 41: Installing Drive Bays

    3. Slide the E1.S module in the slot and push forward until the module seats in the connector. 4. To secure the module in the chassis, close the latch until it catches the latch-release button. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 42 Install and Upgrade Field Replaceable Units Installing Drive Bays Figure 28: Inserting the E1.S module in the slot Latch-release button Latch (shown in open position) E1.S Module Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 43 2. Install the drive into the slot and push forward until the drive seats in the connector 3. To secure the drives in the chassis, secure the screws on each side of the drive faces Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 44: Replace (Remove And Install) Fan Tray

    2. Remove the two screw that secure the fan tray in the chassis. 3. Disconnect the fan cables from the motherboard. 4. Remove the fan tray by lifting up out of the chassis. 5. To install, perform these operations in reverse. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 45: Remove Small Form Pluggable Modules

    The latching mechanism used on many SFPs locks the SFP into place when cables are connected. Do not pull on the cabling in an attempt to remove the SFP. Step 3 Disconnect the SFP latch. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 46 Use a pen, screwdriver, or other small straight tool to gently release a bale-clasp handle if you cannot reach it with your fingers. Step 4 Grasp the SFP on both sides and remove it from the device. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 47: Laser Safety Guidelines

    Viewing the laser output with certain optical instruments, for example, eye loupes, magnifiers, and microscopes, within a distance of 100 mm, may pose an eye hazard. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 48 Laser Safety Guidelines Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...

Table of Contents