Cisco Catalyst 8300 Series Hardware Installation Manual

Edge ucpe
Hide thumbs Also See for Catalyst 8300 Series:

Advertisement

Quick Links

Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide
First Published: 2023-09-05
Americas Headquarters
Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000
800 553-NETS (6387)
Fax: 408 527-0883

Advertisement

Table of Contents
loading

Summary of Contents for Cisco Catalyst 8300 Series

  • Page 1 Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide First Published: 2023-09-05 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA 95134-1706 http://www.cisco.com Tel: 408 526-4000 800 553-NETS (6387) Fax: 408 527-0883...
  • Page 2 © 2023 Cisco Systems, Inc. All rights reserved.
  • Page 3: Table Of Contents

    C H A P T E R 1 Overview of Cisco Catalyst 8300 Series Edge uCPE Cisco Catalyst 8300 Series Edge uCPE Chassis Location of Labels on Cisco Catalyst 8300 Series Edge uCPE Hardware Features Status Indicators and LEDs for Gigabit Ethernet Ports...
  • Page 4 Installing and Removing a Network Interface Module (NIM) Installing Pluggable Interface Module Installing Drive Bays Replace (Remove and Install) Fan Tray Remove Small Form Pluggable Modules C H A P T E R 5 Laser Safety Guidelines Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 5: Overview Of Cisco Catalyst 8300 Series Edge Ucpe

    • Cisco Catalyst 8300 Series Edge uCPE Chassis, on page 1 • Location of Labels on Cisco Catalyst 8300 Series Edge uCPE, on page 3 • Hardware Features, on page 4 •...
  • Page 6 M.2 disk slot (75 GB USB M.2, 600 GB or 2 TB NVMe disk) Chassis- Bezel Side PSU Slot GND Lug or Ground Point Fan Tray Chassis On/off Switch Visible through chassis. PSU Slot Chassis- Internal DIMM slots x 4 Fan Tray Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 7: Location Of Labels On Cisco Catalyst 8300 Series Edge Ucpe

    Location of Labels on Cisco Catalyst 8300 Series Edge uCPE The figure below shows the location of the labels on the Cisco Catalyst 8300 Series Edge uCPE. Labels are located at the same location on all the Cisco Catalyst 8300 Series Edge uCPE.
  • Page 8: Hardware Features

    Status Indicators and LEDs for Gigabit Ethernet Ports The front panel Gigabit Ethernet ports has eight ports: four RJ45 ports and four SFP ports. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 9 LED indicator for blue environmental status beacon CPU Activity Link Activity for 0/0 - 0/2 Link for GEO/0~0/2 copper ports Link/LOS for SFP 0/3~0/6 E1.S Activity Hazard Fault symbol SSD Activity for U.2 slot Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 10 (setup menu) RED blinking — x86 Secure boot failure RED - x86 is UP but BIOS is not fully UP yet (bios post cmplt not set) OFF - x86 in power-off state Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 11: Fans, Ventilation, And Airflow

    Under all conditions, the fans operate at the slowest speed possible to conserve power and reduce noise. When necessary, the fans operate at higher speeds for different environmental conditions. Figure 1: Airflow direction from front to back Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 12 Overview of Cisco Catalyst 8300 Series Edge uCPE Fans, Ventilation, and Airflow Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 13: Prepare For Installation

    Required Tools and Equipment, on page 13 Safety Recommendations and Warnings Review the safety warnings listed in Regulatory Compliance and Safety Information for the Cisco Catalyst 8300 Series Edge uCPE before installing, configuring, or maintaining the device. Read the following safety guidelines before you install this product: Warning This warning symbol means danger.
  • Page 14: Safety With Electricity

    • Never touch uninsulated ethernet wires or terminals unless the ethernet line is disconnected atthe network interface. • Use caution when installing or modifying ethernet lines. • Remove power cables from all installed power supplies before opening the chassis. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 15: Site Requirements

    19 lb (9.015 kg) when fully configured To place the system in a proper location, it is necessary to know the dimensions of the device's chassis. The Catalyst 8300 uCPE can be: • Mounted on a desktop Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 16: Power Guidelines And Requirements

    This unit might have more than one power supply connection. To reduce risk of electric shock, all connections must be removed to de-energize the unit. Statement 1028. Network Cabling Specification • Ethernet cables for RJ45 ports. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 17: Required Tools And Equipment

    • Cables for connection to the WAN and LAN ports (depending on the configuration) Note If you order the required cables when you purchase the device, the cables ship along with the product. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 18 Prepare for Installation Required Tools and Equipment Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 19: Install The Cisco Catalyst 8300 Series Edge Ucpe

    Install the Cisco Catalyst 8300 Series Edge uCPE • Unpacking the Device, on page 15 • Installing the Cisco Catalyst 8300 Series Edge uCPE, on page 15 • Grounding the Chassis, on page 25 • Initial Server Setup, on page 26 Unpacking the Device The device, accessory kit, publications, and any optional units may be shipped in more than one container.
  • Page 20 Attach one mounting bracket to each side of the device as shown in following figures. Four screws are required to attach each bracket to the device. Screws are provided with the mounting kit to attach the screws to the device. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 21 RFID is provisioned. The following image shows the brackets secured to the I/O-face in the recessed position (RFID is applied). If flush securing is desired, slide the bracket forward and secure the other 4 bracket-securing holes. Note Recessed mounting is not supported on the PSU-face. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 22 Install the Cisco Catalyst 8300 Series Edge uCPE Installing the Cisco Catalyst 8300 Series Edge uCPE Figure 3. Rack mount brackets applied recessed from I / O - f a c e RFID provisioned (reference) Rack-mount bracket Screws Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 23 If the small holes do not line up with the rack holes, you must raise or lower the brackets to the next rack hole. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 24 #12 screws. 4. Tighten the screws to the appropriate torque value for your equipment. Figure 5. Mounting the Chassis on the Rack- Front (I/O face) shown for 19 inches RM Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 25 Install the Cisco Catalyst 8300 Series Edge uCPE Installing the Cisco Catalyst 8300 Series Edge uCPE Securing screws (customer provided) 19" Rack upright Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 26 4-point Mounting in a Cabinet 4-point mounting is supported for 19” cabinets that require rear-support of the device. A range of rear-support depths is supported depending whether flush-mounting or recessed-mounting is chosen. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 27 For safety reasons, the device must be mounted as shown in the following figure with the I/O-face to the side. I/O-face may be oriented to the right (as shown) or to the left, but only a side of the chassis may be facing down. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 28 Route the cables so that they do not put a strain on the connectors or mounting hardware. For safety reasons, the chassis may only be mounted with ports going out in left or right direction. Do not mount the chassis with ports facing upward or downward direction. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 29: Grounding The Chassis

    Warning To reduce risk of electric shock, when installing or replacing the unit, the ground connection must always be made first and disconnected last. Statement 1046 Figure 1. Grounding the Chassis Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 30: Initial Server Setup

    • When you see the prompt, you can press F2 to get into the setup (BIOS) to change some settings. • After you have performed the required configuration, save the setup and continue to boot. For more information on initial server setup see, Hardware Installation Guide for Cisco Catalyst 8300 Series Edge uCPE.
  • Page 31 Remote Connection Procedure • Plug in your terminal server to the Serial port (Refer to Front panel of Chassis). • Telnet into the console and perform the necessary configuration using corresponding commands. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 32 Install the Cisco Catalyst 8300 Series Edge uCPE Initial Server Setup Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 33: Install And Upgrade Field Replaceable Units

    2. Place the chassis on a flat surface. 3. Remove the screws at top of the chassis cover. 4. Remove screws from each side and top of the device as shown in the above figure. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 34: Installing A Dual In-Line Memory Module (Dimm)

    2. Locate the DIMM slots on the device. There are four DIMM slots in the chassis and you can install the DIMM module on any of the slots. 3. Make sure that both latches on the DIMM connector are in the open position. Figure 2. DIMM orientation Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 35: Removing A Dimm

    4. Place the DIMM in an antistatic bag to protect it from ESD damage. 5. Replace the chassis cover. Installing the M.2 Storage Module The M.2 storage modules come with different storage capacities and can be replaced through the front panel if required. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 36 Note The disk used in M.2 is also the boot disk. If you replace the M.2 disk, you must reinstall Cisco NFVIS operating system once again. 4. Plug in the new M.2 storage module in the same location and secure it with the screws.
  • Page 37: Installing And Removing A Network Interface Module (Nim)

    2. Loosen the screws to remove NIM blank cover. 3. Insert the NIM into the slot. 4. Tighten the screws to secure the NIM in the slot. Figure 1. Securing the NIM in the slot Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 38: Installing Pluggable Interface Module

    All module slots must have a module or blank installed for the product to work thermally and for safety purposes. Installing Pluggable Interface Module To insert the PIM into the router, do these steps: 1. Insert and then gently push the PIM into the pluggable slot until firmly fixed. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 39: Installing Drive Bays

    3. Slide the E1.S module in the slot and push forward until the module seats in the connector. 4. To secure the module in the chassis, close the latch until it catches the latch-release button. Figure 1: Inserting the E1.S module in the slot Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 40 Install and Upgrade Field Replaceable Units Installing Drive Bays Latch-release button Latch (shown open position) E1.S Module Figure 2: Securing the E1.S module in the chassis Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 41: Replace (Remove And Install) Fan Tray

    Figure 3: Installing the SSD 2.5" drives Screws SSD 2.5" Drives Replace (Remove and Install) Fan Tray 1. Remove the top cover. 2. Remove the two screw that secure the fan tray in the chassis. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 42: Remove Small Form Pluggable Modules

    Statement 1051 Caution The latching mechanism used on many SFPs locks the SFP into place when cables are connected. Do not pull on the cabling in an attempt to remove the SFP. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 43 Use a pen, screwdriver, or other small straight tool to gently release a bale-clasp handle if you cannot reach it with your fingers. Step 4 Grasp the SFP on both sides and remove it from the device. Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 44 Install and Upgrade Field Replaceable Units Remove Small Form Pluggable Modules Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 45: Laser Safety Guidelines

    Viewing the laser output with certain optical instruments (for example, eye loupes, magnifiers, and microscopes) within a distance of 100 mm may pose an eye hazard. Statement 1056 Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...
  • Page 46 Laser Safety Guidelines To install an SFP module in your device, perform these steps: Cisco Catalyst 8300 Series Edge uCPE Hardware Installation Guide...

Table of Contents