Safety instructions
Periodic inspection/inspection after a fall
To ensure the function and safety of the components, a safety
inspection of the SkyReach Anchor, the attachments and the
PFPE, needs to be done by a competent person at least once
every 12 months. The inspections must be documented into a
component record.
If an accident has occurred, e.g. a person has fallen, the items
must be immediately withdrawn from use and inspected by a
competent person according to the manufacturer´s safety check.
Please contact Combisafe for more information regarding
inspections and associated documentation.
NOTE
The SkyReach Anchor is designed to deform if a fall occurs, to
absorb the energy and reduce the arising forces. When tested,
the maximum vertical deflection of the anchor point is 0,7 m.