Loading System MkII
Figure 27. Insertion of Top Frame into Corner Posts. Check the
position of Insertion Marking Label when Top Frame is slotted into
the Corner Posts, highlighted in the illustration to the left.
Now the Loading System MkII Base is completed as an
assembled unit and equipped with either the Top Column 4.7 or
the SkyReach Adaptor 5.9. If concrete or gravel is preferred as
ballast option, or if other ballast option is chosen please proceed
to step 9. If the Precast Kentledge is used as ballast, please
proceed to step 10.
9. If concrete is the chosen ballast option, fill the box in the base
with concrete. Concrete must be distributed evenly on the
bottom board.
If gravel is the preferred ballast option, fill the box up with
gravel, compact well and make sure there is no gap in the
gravel box to avoid losing gravel out of the box.
If a non-standard ballast option is chosen, make sure that the
ballast is distributed centrally and secured against free move-
ment. The ballast must be placed inside the unit in between
the Bottom Frame and the Top Frame at all times when in
use.
NOTE
In all cases ballast must be centred in the unit and its weight
must be minimum 1500kg. Otherwise the safe function of
Loading System MkII is not warranted.