4.2. Cut twelve 70x45 timber ribs to 920 mm in length and four
pieces of 18 mm Formwork Plywood, complying with EN
636-3, to the format 1285x920 mm and cut out a notch in
one corner as shown in Figure 19. Make four similar side
board units according to these instructions, and then fix the
ribs to the boards with wood screws as in Figure 19.
Figure 19. Dimensions for the concrete side board.
1. 3 x Timber Rib (45x70x920)
2. Concrete Side Board
4.3. Place the four Concrete Side Board assembly units equally
one after another onto the Bottom Board located in the
Base, with the notch facing down and the Timber Ribs lean-
ing towards the Formwork Supports, see Figure 20. Make
sure to place all the units overlapping so that all the side-
board units get the same support when leaning against the
Formwork Supports.
NB. Suitable base and side boards are available from
Combisafe, order code 11595