Loading System MkII
Recommended operation method
Once an operative is wearing the correct harness he can then
attach the 0.3 m extender to the harness by looping it through
itself, and then attach the other end of the extender to the
Retractable Fall Arrest Block, using the karabiner fixing.
NOTE
The operative must be connected to the system before
accessing the flatbed.

Double Unit usage

A Double Unit is required, when loading or unloading a flatbed
with a length between 8 and 14 m, which will fit into the loading
zone as described in Figure 36. A Double Unit consists of two
Loading System MkII Base units with two SkyReach Anchor units,
two 10 m Falcon Fall Arrest Blocks, one full body harness and
two Top Column 4.7 units (complete kit Art. No. 8809) or two
SkyReach Adaptor 5.9 units (complete kit Art. No. 8810), please
see chapter Technical Data, Figure 3.
This method is based on a width of the flatbed loading area
greater or equal to 2,4 m. For any width less than mentioned, or
for a flatbed length greater than 14 m, please contact Combisafe
for advice.
The operative must be connected to both Loading System MkII
units at the same time before accessing the flatbed.
The Bases must be symmetrically positioned with respect to the
loading zone according to Figure 36 below.
Figure 36. Working area illustration for a Double Unit usage.
1. Loading Zone
2. Operative