Honeywell COMBISAFE 8800 User Instructions page 29

Loading system mkii including 8100 skyreach anchor
Table of Contents

Advertisement

Loading System MkII
6. When using the SkyReach in the Loading System MkII Base
unit, the Top Column 4.7 can be used to provide an anchor
point located 4,7 m above ground level. If greater working
height is preferred, then chose the SkyReach Adaptor 5.9
instead. With this solution, the anchor point will be located
5,9 m above ground level. The following instructions can be
applied to both of the solutions but the illustrations are show-
ing the Top Column 4.7 only.
With the Top Frame still standing on the ground, insert the
Top Column 4.7/SkyReach Adaptor 5.9 unit into the Top
Frame, observing that the Insertion Marking Label is in posi-
tion, see Figure 25.
Figure 25. Insertion Marking Label on Top Column 4.7.
NOTE
Make sure that the Top Column 4.7/SkyReach Adaptor 5.9 is
inserted the correct length into the Sleeve. Insertion Marking
Label on Top Column 4.7/SkyReach Adaptor 5.9 must be
aligned with upper edge of Top Frame Sleeve for a safe and
proper installation.
7. Using a forklift truck, place the forks underneath the hori-
zontal tubes of the Top Frame, spread the forks as wide as
possible and then, if needed, secure the Top Frame assembly
with the two supplied Combistraps before lifting. Straps shall
be attached diagonally to each fork to ensure a safe lift, see
Figure 26 below. Remember that the straps should be tight-
ened firmly.
Assembly
29

Advertisement

Table of Contents
loading

Table of Contents