H.323 Endpoint-To-Endpoint Call Setup With A Common Gatekeeper - Cisco ATA 186 Administrator's Manual

Cisco analog telephone adaptor administrator's guide
Hide thumbs Also See for ATA 186:
Table of Contents

Advertisement

Appendix D
H.323 Signaling
H.323 Signaling Scenarios

H.323 Endpoint-to-Endpoint Call Setup with a Common Gatekeeper

Figure D-2
illustrates a Cisco ATA initiating a connection to another Cisco ATA that is registered with
the same H.323 gatekeeper. This scenario features registration with no authentication.
Note
This scenario assumes that the H.323 configuration employs Slow Start Signaling with tunneling
capability.
Figure D-2
H.323 Endpoint-to-Endpoint Call Setup with a Common Gatekeeper
Gatekeeper 1
Endpoint 2
Endpoint 1
V
ARQ
ACF/ARJ
Set-Up
Call Proceeding
ARQ
ACF/ARJ
Alerting
Connect
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator's Guide (H.323)