Opflags - Cisco ATA 186 Administrator's Manual

Cisco analog telephone adaptor administrator's guide
Hide thumbs Also See for ATA 186:
Table of Contents

Advertisement

Chapter 5
Parameters and Defaults
Table 5-5
SigTimer Parameter Bit Definitions (continued)
Bit Number
Definition
20-25
Not used by H.323.
26-27
Minimum hook flash time—The minimum on-hook time required for hook flash event.
Range: 0 to 3
Default: 0 (60 ms)
Other possible values: 1=100 ms, 2=200 ms, 3=300 ms.
28-31
Maximum hook flash time—The maximum on-hook time allowed for hook flash event.
Range: 0 to 15
Default: 0 (1000 ms)
Other possible values: 1=100 ms, 2=200 ms, 3=300 ms, 4=400 ms, 5=500 ms, 6=600 ms, 7=700 ms, 8=800
ms, 9=900 ms, 10=1000 ms, 11=1100 ms, 12=1200 ms, 13=1300 ms, 14=1400 ms, 15=1500 ms.

OpFlags

Description
This parameter enables/disables various operational features.
See
Value Type
Bitmap
Default
0x2
Voice Configuration Menu Access Code
323
Related Parameters
Table 5-6
OpFlags Parameter Operational Features to Turn On or Off
Bit Number
Definition
0
If Bit 0 = 0, the TFTP configuration filename supplied by the DHCP server overwrites the default filename for
each Cisco ATA.
If Bit 0 = 1, the default Cisco ATA filename is always used.
1
If Bit 1 = 0, the Cisco ATA probes the static network router during the power-up process.
If Bit 1 = 1, static network router probing is disabled.
2
Reserved.
OL-4008-01
Table 5-6 on page 5-33
for bit definitions of this parameter.
TftpURL, page 5-5
DHCP, page 5-7
VLANSetting, page 5-34
Cisco ATA 186 and Cisco ATA 188 Analog Telephone Adaptor Administrator's Guide (H.323)
Operating Parameters
5-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ata 188

Table of Contents