Fluid Type; Reynolds Correction - GE AquaTrans AT868 User Manual

Ultrasonic flow transmitter for water (1- & 2-channel)
Hide thumbs Also See for AquaTrans AT868:
Table of Contents

Advertisement

September 2004

Fluid Type

Reynolds Correction

2-10
1. The selections for fluid type vary depending on whether the
Tracking Window is enabled or disabled. Press [
select the desired fluid and press [ENTER]. Refer to Table 2-2
below for a list of available fluids.
Table 2-2: Fluid Types
Tracking Windows =
NO
WATER
OTHER
2. If you selected OTHER, enter the additional information as
prompted by using the arrow keys. Press [
cursor to desired location and press
decrease the number and press [ENTER].
]
1. Press [
and [ ] to select whether to activate or deactivate the
Reynolds Correction Factor and press [ENTER].
Note: Typically, Reynolds Correction is set to active.
2. Do one of the following:
If you selected OFF, enter the Calibration Factor and press
[ENTER]. Then, proceed to one of the following sections:
For Clamp-on Transducers - proceed to Number of
Traverses and Transducer Spacing on page 2-12.
For Wetted Transducers - The meter returns to the Channel
PROGRAM window. At this point, you can continue
programming in this submenu as desired. To leave the
Channel PROGRAM window, press [ESC] three times. To
complete setting up the meter, you must enter data in the
GLOBL-SYSTM submenu as described on page 2-22.
If you selected ACTIV, proceed to KV Input Selection on
page 2-11.
]
and [ ] to
YES
W100 (Water, 0°-100°C)
W260 (Water, 0°-260°C)
Oil, Tracking
OTHER
]
and [ ] to move the
[ ] and [ ]
to increase or
Programming Site Data