Transducer Specifications - GE AquaTrans AT868 User Manual

Ultrasonic flow transmitter for water (1- & 2-channel)
Hide thumbs Also See for AquaTrans AT868:
Table of Contents

Advertisement

September 2004
Transducer
Specifications
Wetted Transducers
8-4
Temperature Range
o
Standard: -40
to 212
Optional (overall range): -328
Pressure Range
Standard: 0 to 3,000 psig (0.1013 to 20 MPa).
Optional: Higher pressures available on request.
Frequency:
Standard: 1 MHz (1-in. process connection) or 2 MHz
(3/8-in. process connection).
Optional: 500 kHz or 4 MHz.
Materials
Standard: 316 SS
Optional (for isolating PanAdapta Plugs): Titanium, Hastelloy,
Monel, CPVC, PVDF and others.
Conduit Connections:
1-in. NPTM or 3/8-in. NPTM.
Process Connections:
Standard: 1-in. NPTM or 3/8-in. NPTM.
Optional: RF flanged, socket weld, fuse bond & others.
Mounting:
Spoolpiece, hot tap or cold tap.
Housing:
Standard: None (splashproof).
Optional: Explosion-proof, Div. 1, Class 1, Group C&D,
INIEX-Certified EEx d IIC T6 or weatherproof (NEMA 4, IP65).
Other Options:
Transducers for special applications; fixtures; no organic bonds or
insulators; cooling jackets for high temperatures. Please consult
GE Infrastructure Sensing for details.
o
o
o
F (-40
to 100
C).
o
o
to 500
F (-200
o
o
to 260
C).
Specifications

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents