Cisco ONS 15454 M6 Installation Manual page 90

Hide thumbs Also See for ONS 15454 M6:
Table of Contents

Advertisement

DLP-G570 Install the DC Power Module in the ONS 15454 M6 Shelf
Caution
Always use the supplied ESD wristband when working with a powered ONS 15454 M6. For detailed instructions
on how to wear the ESD wristband, see the
Cisco ONS
Procedure
Step 1
Disconnect the power source and remove the power connections from the B-side power module (installed in
slot B).
Step 2
Unscrew the holding screw that secures the 15454-M6-AC2 power module.
Step 3
Pull the 15454-M6-AC2 power module clear from the ONS 15454 M6 chassis.
Step 4
Install the 15454-M6-AC power module as described in the
ONS 15454 M6 Shelf, on page
Step 5
Install power on the 15454-M6-AC power module as described in the
to the ONS 15454 M6 Shelf , on page
Note
Step 6
Perform steps 1 to 5 for the other power module (installed in slot A).
Step 7
Return to your originating procedure (NTP).
DLP-G570 Install the DC Power Module in the ONS 15454 M6 Shelf
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Installing the ONS 15454 M6 Shelf
90
Platforms.
85.
While replacing the power modules, do not provision or install any line cards when the ONS 15454
M6 chassis is in the mixed power mode (with both 15454-M6-AC and 15454-M6-AC2 power
modules installed). Card provisioning and installation must be done only after both the slots have
the same type of power modules.
This procedure installs the 15454-M6-DC, 15454-M6-DC20, or 15454-M6-DC40
DC power module in the ONS 15454 M6 system.
#2 Phillips Dynamometric screwdriver
NTP-G252 Install the ONS 15454 M6 Shelf , on page
NTP-G259 Open and Remove the Standard Door of the ONS 15454 M6
Shelf , on page
• Connect the chassis to the office ground. For detailed instructions on how
to ground the chassis, see the
for Cisco CPT and Cisco ONS
Required
Onsite
None
Electrostatic Discharge and Grounding Guide for Cisco CPT and
DLP-G569 Install the AC Power Module in the
100.
57.
Electrostatic Discharge and Grounding Guide
Platforms.
Installing the ONS 15454 M6 Shelf
NTP-G256 Install Power and Ground
24.

Advertisement

Table of Contents
loading

Table of Contents