NTP-G252 Install the ONS 15454 M6 Shelf
Case
Side to Side
ETSI Front to Rear
ETSI Front to Side
ANSI Front to Rear
ANSI Front to Side
NTP-G252 Install the ONS 15454 M6 Shelf
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Warning
Stability hazard. The rack stabilizing mechanism must be in place, or the rack must be bolted to the
floor before you slide the unit out for servicing. Failure to stabilize the rack can cause the rack to tip
over. Statement 1048
Warning
This product requires short-circuit (overcurrent) protection, to be provided as part of the building
installation. Install only in accordance with national and local wiring regulations. Statement 1045
Installing the ONS 15454 M6 Shelf
24
Deflector Configuration
Bulk Chassis Flow, CFM
No deflectors
215.3
Inlet and Outlet
97.7
Only Inlet
187.7
Inlet and Outlet
120.5
Only Inlet
193.5
This procedure installs the shelf.
• #2 Phillips Dynamometric screwdriver
• Medium slot-head screwdriver
• Small slot-head screwdriver
• ETSI only:
• Six M6 x 20 pan-head Phillips mounting screws
• ANSI only:
• Six #12-24 x 3/4 pan-head Phillips mounting screws
NTP-G305 Unpack and Inspect the ONS 15454, ONS 15454 M2, and ONS 15454
M6 Shelves
Required
Onsite
None
Installing the ONS 15454 M6 Shelf
295.6
135.8
258.6
166.9
268.6