Cisco ONS 15454 M6 Installation Manual page 20

Hide thumbs Also See for ONS 15454 M6:
Table of Contents

Advertisement

DLP-G769 Install Air Plenum for ONS 15454 M6 Shelf in ETSI Configuration
Tools/Equipment
Required/As Needed
Onsite/Remote
Security Level
Procedure
Step 1
Install the ETSI adapter plates on the horizontal air plenums.
Step 2
Align the screws to fix the adapter plates to the shelf. Insert the screws and tighten them to a torque value of
11.5 in-lb (1.3 N-m).
Figure 20: Installing the adapter plates on the horizontal air plenum
Step 3
Place the horizontal plenum below the chassis slot in the ETSI cabinet.
Step 4
Install the wing head screws provided with the kit, and tighten to a torque value of 11.5 in-lb (1.3 N-m).
Installing the ONS 15454 M6 Shelf
20
• #2 Phillips Dynamometric screwdriver
• Medium slot-head screwdriver
• Small slot-head screwdriver
• Screws: M6.0 x 20 pan-head Phillips screws (8)
• Wing head screws (8)
• Adapter plates
• One air plenum kit (horizontal and vertical air plenum)
As needed
Onsite
None
Installing the ONS 15454 M6 Shelf

Advertisement

Table of Contents
loading

Table of Contents