Installing the ONS 15454 M6 Shelf
The fiber diameter is a maximum of 2 mm and the CAT5 cable diameter is a maximum of 5 to 6 mm. You
need to determine your fiber size according to the number of cards and ports installed on each side of the
shelf. For example, if your port combination requires 36 fibers, 3-mm (0.11-inch) fiber is adequate. If your
port combination requires 68 fibers, you must use 2-mm (0.7-inch) or smaller fibers.
Note
The minimum distance between the fiber LC connector and the bulk attenuator must be at least 50 cm. This
is the minimum distance required to place the bulk attenuator outside the shelf from any port of a card.
Cable and Fiber Routing
Cable and fiber routing accommodates all the high-density cards for line card connections in ONS 15454 M6.
The exit of the fibers and cables is split into two channels. The line card from slot 1 to 4 exits from the lower
right side, and the line card from 5 to 8 exit from the upper right side. (See the following figure.)
Figure 91: Cable and fiber routing
NTP-G290 Install the Cable and Fiber Modules
Purpose
Tools/Equipment
Prerequisite Procedures
This procedure installs the cable and fiber modules in the ONS 15454 M6 system.
#1 Phillips cross-head PH screwdriver
None
Cable and Fiber Routing
Installing the ONS 15454 M6 Shelf
121