Dealers will initially enroll their customers for web services during account programming
through the AlarmNet Direct website. The features that can be enabled include Remote
Access and Multi-Mode. Once enabled, the specific programming fields associated with these
features can be programmed into the communications device either remotely using the
AlarmNet Direct website or locally using the 7720P local keypad programming tool.
U L

Modes of Operation

The IGSMV provides four modes of operation so it can be used with various types of control
panels, as summarized below.
ULC
UL

ECP Mode

 This mode is for use with Honeywell controls that support LRR-ECP communication
 The module connects to the control's keypad terminals and provides 2-way communication
with the control using ECP messaging
 The control treats the module as a Long Range Radio (LRR) device, so program the control
accordingly, including setting the module's proper LRR device address
 Reports are sent in Contact ID format
 The module also supports two hardwire zone trigger inputs (zones 6 and 7)
U L

Zone Trigger Mode

 This mode is for use with controls that do not support LRR-ECP communication nor 4204
Relay Modules
 The module provides six input zones
 Each zone can be configured for +V, -V, or EOLR triggering
UL – For the IGSMV, only the V+ inverted, V– non-inverted, and EOL options have been
evaluated.
 Each zone can be programmed for inverted operation, delayed reporting, and restoral
reporting
 Zone 1 input can distinguish between pulsed and steady signals and report fire or
burglary alarms respectively
 Zone 1 can also be programmed to report LYNX panic (if used with LYNX control)
UL – This feature has not been evaluated by UL.
 Reports are sent in ADEMCO High-Speed format
U L

4204 Mode and Two-4204 Mode

 This mode is for use with Honeywell controls that do not support LRR-ECP
communication, but that do support 4204 Relay Modules
 The module connects to the control's keypad terminals
Remote Access and Multi-Mode have not been evaluated by UL.
Only ECP Mode has been approved for ULC installations.
Only ECP Mode and Zone Trigger Mode have been evaluated.
 Opening and Closing ring back is fully supported.
For the IGSMV, only the V+ inverted, V– non-inverted, and EOL options have been
evaluated.
Opening and Closing ring back is supported by the control panel's digital dialer.