Programming Conventions

Programming is accomplished by answering a series of prompts (questions). Most prompts
require only a [Y]es or [N]o response, while others require a numerical response (ID
numbers, etc.).
The current value is displayed on the second line in parentheses ( ). A "?" indicates an
invalid entry.
Use the [ENTER] key to accept the current entry and proceed to the next prompt. If the
entered value is invalid, pressing [ENTER] re-displays the prompt; the next prompt is not
displayed until a valid answer is entered.
Use the up/down arrow keys to scroll through the programming questions without changing
any values. Press the [ESC] key to go to the end of the list of questions.

ECP Mode Programming

The IGSMV supports ECP messaging to communicate with the control panel. LRR-enabled
control panels send Contact ID format alarms to the IGSMV directly on the 4-wire console
bus. Not all control panels support the LRR interface on ECP, so be sure to check the
Installation and Setup Guide of the control panel to see if it supports this feature.
ULC
Press the [ENTER] key to begin programming.
NOTE: The central station can remotely block access to local device
NOTE: The default programming values for ECP mode are listed in each prompt below.
PROMPTS
Strt Prog Mode?
1
(Y/N)_
Enter Password:
2
3
Program Device?
(Y/N)_
Create Password?
4
(Y/N)_
Change Password?
5
(Y/N)_
Only ECP Mode has been approved for ULC installations.
programming. If this has been done, the following prompt appears:
Table 3-2: Programming a IGSMV for ECP mode only.
ENTRY
OPTIONS
[Y], [N]
[0-9, A-F, N, S,
T, X, Y]
[Y], [N ]
[Y], [N]
[Y], [N]
Section 3: Programming the IGSMV
DESCRIPTION
Enters programming mode.
If a password has been previously assigned, this
prompt appears.
Enter a 4-digit password (0-9, A-F, N, S, T, X, Y).
The next prompt appears.
To begin programming the module, press [Y] and go to
Prompt 9: "Device Mode."
To create a password if none has been assigned, press
[N] and go to Prompt 4: "Create Password."
To change an existing password, press [N] and go to
Prompt 5: "Change Password."
Passwords can be used to protect account and
programming information.
If no password has been assigned, this prompt
appears after pressing [N] at the "Program Device?"
prompt.
If a password is desired, press [Y] and go to "Enter
Password."
If a password has already been assigned, this prompt
appears after pressing [N] at the "Program Device?"
prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without
entering a new one, answer [Y] to the "Change
Password?" prompt, then press the [Enter] key when
prompted for the new password and its confirmation.
Access to Prog
Mode Denied
3-3