NOTE: Zone 4 status is not reported when being
used as the conditional (armed) trigger zone.
When using the IGSMV in 4204 Emulation Mode, DO NOT enable the Long-Range Radio
module in control panel programming. Instead, enable 4204 relay module address(es) and
program the appropriate relay activation functions for the relay-zones being used. In some
control panels, it is called "relay programming" and in others it is called "output device
programming." It is recommended that "close and stay closed" (usually choice 2) action is
selected. Selection of momentary activation will cause the IGSMV to generate an alarm and
NOT a restore, even if the IGSMV is programmed to send a restore for the given zone.
In 4204 mode, messages are reported in ADEMCO High-Speed format. Zone alarms
(status 7) are reported with "1" (alarm) or "3" (restore) displayed in the zone position for the
respective zone (e.g. alarm on zone 2: 5155 5555 7; restore 5355 5555 7). A supervision fault
trouble message is automatically sent if the module detects no activity on its connection to the
control panel. The message is: 5555 5515 5; restore message is: 5555 5535 5.
Refer to Table 3-4 for 4204 Emulation Mode programming and follow the prompts that pertain
to 4204 or Two-4204 mode. A check mark (
mode.

Alternative Mode Programming

Press the [ENTER] key to begin programming
operation being programmed.
NOTE: The central station can remotely block access to local
Table 3-4: Programming a IGSMV for Zone Trigger, 4204 Emulation, or Two-4204 Emulation modes.
PROMPTS
1
Strt Prog Mode?
Y/N_
Enter Password
2
Program Device?
3
Y/N_
Create
4
Password?
Y/N_
device programming. If this has been done, the following
prompt appears:
4204/
ZONE
ENTRY
TRIG.
2-4204
Section 3: Programming the IGSMV
NOTE: Zone 8 status is not reported when being
used as the conditional (armed) trigger zone or if
tamper reporting is enabled.
) indicates whether the prompt applies to that
ollow the prompts for the mode of
and f
OPTIONS
Enters programming mode.
[Y], [N]
[0-9, A-F,
If a password has been previously assigned, this
N, S, T, X,
prompt appears.
Y]
Enter a 4-digit password (0-9, A-F, N, S, T, X,
Y).
The next prompt appears.
[Y], [N]
To begin programming the module, press [Y]
and go to Prompt 9: "Device Mode."
To create a password if none has been assigned,
press [N] and go to Prompt 4: Create Password.
To change an existing password, press [N] and
go to Prompt 5: "Change Password."
[Y], [N]
Passwords can be used to protect account and
programming information.
If no password has been assigned, this prompt
appears after pressing [N] at the "Program
Device?" prompt.
If a password is desired, press [Y] and go to
Prompt 6: "Enter Password."
Access to Prog
Mode Denied
DESCRIPTION