IGSMV / IGSMVCN Installation and Setup Guide
Exiting Programming Mode
To exit the programming mode, press [N] in response to the "REVIEW?" question. Then
press [Y] to the "Exit Prog Mode?" question. Upon exiting, the root file is updated to log the
changes made. A message is displayed telling the user that this step is being executed.
When complete, the message "DONE" is displayed to indicate the file was successfully
uploaded.
If critical configuration changes were made, such as the mode of operation, the IGSMV will
reset to ensure that the programming features are enabled.
If the file is not successfully uploaded, one of the following prompts will be displayed. Follow
the steps shown below until the upload is successful.
Display
Cannot Upload
Try Again? Y/N_
Failed to Update
Root File!
Setting Factory Defaults
To reset the programming options to factory-default values, press [ESC] at the "Exit Prog
Mode?" prompt.
Set Default?
Y/N_
If you press [Y], all programmed values are reset to the original factory settings. PLEASE
NOTE THAT THIS WILL ERASE ANY PASSWORD THAT MAY HAVE BEEN ENTERED.
After pressing [Y], the Create Password prompt appears (see Prompt 4).
3-22
Description
IGSMV module is not yet
initialized.
Network problem, or you
answered "N" to "Cannot Upload
Try Again?" prompt.
Press [Y] to reset factory default values.
Press [N] to cancel this function.
What to do
Wait for RSSI LEDs to be lit.
Press [Y].
Initiate the Force Server Update
Command by pressing the [0] key; refer
to Section 5: Programmer Keyboard
Commands.