IGSMV / IGSMVCN Installation and Setup Guide
PROMPTS
Change
5
Password?
Y/N_
Enter Password
6
Verify Password
7
Exit Prog. Mode?
8
Y/N_
Device Mode
9
(ECP)_
In Zone Trigger mode, the options for Multi-Mode are "Enabled" or "Disabled." If enabled, whenever a zone on the
communication device is triggered, a corresponding email message is sent INSTEAD of normal central station
reports.
Cover tamper will send email event 8. All communication device system events (such as power loss, low battery,
etc.) are still sent to AlarmNet.
Events used to send email messages are defined on the Honeywell Total Connect web site, and must correspond to
events triggering the hardwired zones.
Multi-Mode (email notification) is intended as a convenience for the user, and does not replace Central Station
reporting of critical events (alarms, troubles, etc.).
U L
Multi-Mode has not been evaluated by UL.
Multi Mode
10
(Disabled)_
Important Information Regarding Primary Account (Questions 11-13)
Account information is provided by the central station administrator.
Primary City ID
11
(??)_
12
Primary CS ID
(???)
3-12
4204/
ZONE
ENTRY
TRIG.
2-4204
Important Information Regarding Multi-Mode
OPTIONS
[Y], [N]
If a password has already been assigned, this
prompt appears after pressing [N] at the
"Program Device?" prompt.
Press [Y] if you want to change the password.
NOTE: To clear an existing password, without
entering a new one, answer [Y] to the "Change
Password?" prompt, then press the [Enter] key
when prompted for the new password and its
confirmation.
[0-9, A-F,
This prompt is displayed if [Y] was pressed in
N, S, T, X,
Prompt 4 or 5.
Y]
Enter a 4-digit password (0-9, A-F, N, S, T, X,
Y).
[0-9, A-F,
Re-enter the password as confirmation.
N, S, T, X,
If the password doesn't match the first entry,
Y]
the following is displayed followed by the "Exit
Prog. Mode?" prompt:
Verify Not OK
PSWD not created
Otherwise, the "Exit Prog. Mode?" prompt is
displayed directly.
[Y], [N]
Exits program mode.
Press [N] to go back to Prompt 3.
[ESC]
Press [ESC] to load factory defaults.
Refer to the Exiting Programming Mode
paragraph in this section.
 ECP
Press the [space] key to scroll through the
modes of operation.
 Zone
Trig.
Press [ENTER] to select mode.
 4204
Use Table 3-2 for ECP mode programming.
Emu
 Two
4204s
 Enabled
Enable if you want system events sent by email
to the user.
 Disabled
Disable for normal alarm processing.
[01-99]
Enter the 2-digit primary city ID, 01-99
(decimal).
[01-FE]
Enter the 2-digit primary central station ID
number, 01-FE (HEX).
DESCRIPTION