Honeywell AlarmNet IGSMV Installation And Setup Manual page 50

Internet communication module
Table of Contents

Advertisement

IGSMV / IGSMVCN Installation and Setup Guide
[T]
[X]
[]
(UP
arrow)
[]
(DN
arrow)
[0]
[ENT
ER]
5-4
Battery Charger
OK
Line Voltage
xx.xxV
Test Msg Sent
Reset CPU Y/N
Registering ...
Enter PIN#
Force Server Update?
Y/N
Strt Prog Mode?
Y/N_
The second line of the display shows loaded battery voltage.
An asterisk (*) next to the voltage indicates that this is below
the accepted level.
Press the [Space] key to go to the next field.
Press the backspace [BS] key to go to the previous field.
Battery Charger Status Display
The status of the battery charger circuit of the
IGSMV can be viewed on the 7720P. The status is either OK
or NOT OK.
Press the [Space] key to go to the next field.
Press the backspace [BS] key to go to the previous field.
Line Voltage Display
The line voltage of the IGSMV can be viewed on the 7720P.
An asterisk (*) next to the voltage indicates that this is below
the accepted level.
Press the [Space] key to go back to the System Status
Display.
Press the backspace [BS] key to go to the previous field.
Test Alarm
Sends a Test alarm to AlarmNet. Functional for a registered
IGSMV only. If the device is not registered, a message is
displayed indicating that the command cannot be executed.
Reset the IGSMV.
Pressing [N] returns to diagnostic mode (blank screen = enter
next command or escape).
Pressing [Y] resets the module (blank screen = reset
complete).
Registration
Registers a programmed IGSMV with AlarmNet.
Registration with PIN for Replacement Module
Registers a replacement IGSMV with AlarmNet, once pro-
grammed, using the existing PIN #.
Force Upload of Configuration File to Server
Pressing [Y] will force the device to upload its entire configu-
ration file to the server.
Pressing [N] cancels the operation.
NOTE: If the internet is not available, and the IGSMV
module is not initialized when you enter this command, the
following screen will be displayed:
Cannot Upload
Try Later! _
Wait for the RSSI LEDs to light, indicating the IGSMV
module has completed its initialization, and try again.
Enter Program Mode
Press [Y] to enter program mode; otherwise, press [N].