Honeywell AlarmNet IGSMV Installation And Setup Manual page 39

Internet communication module
Table of Contents

Advertisement

PROMPTS
Rpt Zn4 ONLY if
50
Armed (N)_
Zn5 Trigger Type
51
(V+)_
Invert Zn5 Y/N
52
(N)_
Restore Zn5 Y/N
53
(Y)_
Delay Zn5 (secs)
54
(00)_
55
Rpt Zn5 ONLY if
Armed (N)_
Enable Zn6 Y/N
56
(N)_
Zn6 Trigger Type
57
(V+)_
Invert Zn6 Y/N
58
(N)_
Restore Zn6 Y/N
59
(Y)_
Delay Zn6 (secs)
60
(00)_
Rpt Zn6 ONLY if
61
Armed (N)_
Enable Zn7 Y/N
62
(N)_
63
Zn7 Trigger Type
(V+)_
4204/
ZONE
ENTRY
TRIG.
2-4204
2-
4204
only
2-
4204
only
2-
4204
only
2-
4204
only
4204
only
4204
only
4204
only
4204
only
4204
only
Section 3: Programming the IGSMV
OPTIONS
Reports alarms on zone 4 ONLY if the
[Y], [N]
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 4.
 (V+)
Selects the triggering method for this zone
 (V–)
input.
 (EOLR)
Press the [space] key to scroll through
choices.
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Inverts the alarm and normal states of the
zone 5 trigger; otherwise uses normal input
signal.
[Y], [N]
Enables restore reporting for zone 5.
UL/ULC: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 5.
[00] = no delay
UL/ULC: Must be set to "00."
Reports alarms on zone 5 ONLY if the
[Y], [N]
conditional zone (zone 7 in zone trigger mode;
zone 8 in 2-4204 mode) is triggered (armed).
If [N], always reports alarms on zone 5.
Enables alarm reporting for zone 6.
[Y], [N]
If [N], skip to Prompt 62: "Enable Zn7."
 (V+)
Selects the triggering method for this zone
 (V–)
input.
Press the [space] key to scroll through
 (EOLR)
choices.
UL: V+ must be set as inverted and V– as
non-inverted.
[Y], [N]
Inverts the alarm and normal states of the
zone 6 trigger; otherwise uses normal input
signal.
[Y], [N]
Enables restore reporting for zone 6.
UL/ULC: Must be set to "Y."
[01-15]
Defines the reporting delay in seconds for
zone 6.
[00] = no delay
UL/ULC: Must be set to "00."
Reports alarms on zone 6 ONLY if the
[Y], [N]
conditional zone (zone 7 in zone trigger mode;
zone 4 in 4204 mode; zone 8 in 2-4204 mode)
is triggered (armed).
If [N], always reports alarms on zone 6.
[Y], [N]
Enables alarm reporting for zone 7.
If [N], skip to Prompt 70: "Use DHCP."
 (V+)
Selects the triggering method for this zone
input.
 (V–)
Press the [space] key to scroll through
 (EOLR)
choices.
UL: V+ must be set as inverted and V– as
non-inverted.
DESCRIPTION
3-19