Replacing An Existing Module Using The Programming Tool; Register By Phone - Honeywell AlarmNet IGSMV Installation And Setup Manual

Internet communication module
Table of Contents

Advertisement

Registration BAD
Pri ID – Need PIN
Registration BAD
ID – Need PIN
2nd
Registration BAD
Pri&2
– Need PIN
nd

Replacing an existing module using the programming tool

Enter PIN#
Registering ...
Registration
SUCCESS
Registration BAD

Register by Phone

You can register the module by calling the AlarmNet Technical Assistance Center (TAC) at
1-800-222-6525. You will need the following information:
 MAC number (found on the label).
 Subscriber information (provided by the central station), including a city code, CSID, and
a subscriber ID.
 When instructed to do so, triple-click the tamper switch to complete the registration.
Displayed if this is a repair/replacement, or an error was made in
programming the Primary account information of IGSMV for an
existing account. This prompt appears for 2 seconds. See the
Replacing an existing module section below for further displays.
This prompt is displayed if this is a repair/replacement, or an error
was made in programming the Secondary account information of
IGSMV for an existing account. This prompt appears for 2 seconds.
See the Replacing an existing module section below for further
displays.
This prompt is displayed if this is a repair/replacement, or an error
was made in programming BOTH the Primary and Secondary
account information of
IGSMV for an existing account. This prompt appears for 2 seconds.
See the Replacing an existing module section below for further
displays.
This prompt appears after pressing the [Shift} and down arrow []
on the 7720P.
Note: If it is necessary to exit registration mode, press ESC from
the 7720P programming tool.
Enter a 4-digit alphanumeric PIN number provided by your central
station, your dealer or an authorized AlarmNet representative.
Press the [Enter] key.
The registration message is sent and the unit waits for
acknowledgement.
If the PIN is valid, the new IGSMV is registered and the old unit
unregistered. Additionally, AlarmNet sends a substitution alarm to
the central station.
If you entered an invalid PIN, the appropriate message is displayed
depending on which account number is being replaced (see above for
exact wording). The registration process is repeated.
NOTE: Each attempt causes a substitution alarm to be sent to the
central station.
Section 4: Registration