4.5.2 Parameterization

To program input 2 for the pulse comparison with input 1, send the following parameter file to the EK280
using the parameterization program "enSuite" (see chapter 3.6
EK280 - Input 2 = Pulse Comparison.wpp
The deviation amount between the two pulse generators, above which a warning is triggered, is editable.
The default is 4 ("maximum number of disturbance pulses") within a 4000 pulse ("pulse window per
disturbance pulses").
This setting can be updated using the EK280 keypad or with enSuite:
a) On the "Serv." display tab of the EK280 keypad:
Data book >
Inputs
Data book >
Inputs
b) With enSuite under "Parameterize online" > "Parameter":
Data book >
Inputs
Data book >
Inputs
The maximum number of error pulses is
The pulse window is
Application Manual
>
L1.I2
Maximum number of disturbance pulses (i.e. 4)
>
L2.I2
Pulse window per disturbance pulses (i.e. 1000)
>
Limit 1 for monitoring status
input 2 "L1.I2"
>
Limit 2 for monitoring input 2
"L2.I2"
L1.I2
L1.I2 L2.I2
(i.e. here 4 1000 = 4000).
"Send parameter
Maximum number of disturbance pulses
(i.e. 4)
Factor for pulse window per disturbance
pulses (i.e. 1000)
(i.e. here 4).
file", page 10):