Operating instructions for
consumers
Electronic index EI
Contents
Contents
Electronic index EI . . . . . . . . . . . . . . . . . . . . . 
Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Safety. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Checking the usage . . . . . . . . . . . . . . . . . . . . . 
Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . 
Operating the electronic index . . . . . . . . . . . . 
Navigating within the menu . . . . . . . . . . . . . . 
Releasing the valve . . . . . . . . . . . . . . . . . . . . . 4
Technical data . . . . . . . . . . . . . . . . . . . . . . . . . 5
Logistics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Contact . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Safety
Safety
Please read and keep in a safe place
carefully before installing or operating. Following the
installation, pass the instructions on to the opera-
tor. This unit must be installed and commissioned
in accordance with the regulations in force. These
instructions can also be found at www.docuthek.com.
Explanation of symbols
• ,  ,  ,  ... = Action
Liability
We will not be held liable for damage resulting
from non-observance of the instructions and non-
compliant use.
Safety instructions
Information that is relevant for safety is indicated in
the instructions as follows:
alpha
DANGER
Indicates potentially fatal situations.
WARNING
Indicates possible danger to life and limb.
CAUTION
Indicates possible material damage.
All interventions may only be carried out by qualified
gas technicians. Electrical interventions may only be
carried out by qualified electricians.
Conversion, spare parts
All technical changes are prohibited. Only use OEM
spare parts.
Changes to edition .
The following chapters have been changed:
-
Checking the usage
-
Logistics
GB-1
Please read through these instructions
= Instruction

Advertisement

loading

Summary of Contents for Honeywell Themis alpha EI2

  • Page 1: Table Of Contents

    03250953 Safety Safety 1000106503-002-06 Please read and keep in a safe place www.docuthek.com   Operating instructions for Please read through these instructions consumers carefully before installing or operating. Following the installation, pass the instructions on to the opera- Electronic index EI tor.
  • Page 2: Checking The Usage

    ATEX Checking the usage ▷ The electronic index is suitable for use in potentially Electronic index EI.00, EI.05, EI.06, explosive atmospheres. For the exact use (zone), EI. for diaphragm gas meters BK-G...E, see ATEX sticker on the diaphragm gas meter or BK-G...ET or BK-G...ETe see the operating instructions for diaphragm gas Electronic index for reading out absolute meter read-...
  • Page 3: Navigating Within The Menu

    User keys, selection key and symbols Menu overview ▷ You can navigate through the menu using the The display can differ depending on the parameteriza- tion or communication module. user keys  and the selection key  . Symbol Meaning Navigate to the left or the right on each level using the user keys.
  • Page 4: Releasing The Valve

    Date and time Electronic index with communications module: ▷ Information on the date and time display. ▷ The symbol is displayed if, for example, the tolerance between the internal time recording Date and time and the actual time is too large. This can lead 2011 to invalid consumption data.
  • Page 5: Assistance In The Event Of Malfunction

    ▷ If the release procedure has failed (message:  Once the valve has been released, the following display appears: “Gas flow check failed”), the valve will remain closed. Please contact your meter operator/ Valve open safety check gas supplier. CHECK IF 4 The message must be confirmed by pressing the selection key.
  • Page 6: Logistics

    Maximum allowable ambient temperature range: see ATEX suitability can be found in the operating in- type label/index plate. structions of the respective communication module. Data logger for historic meter readings: The UMI interface features the following parameters: up to 60 weeks in 30-minute intervals. –...