EK280

4.4.2 Parameterization

Parameterization can be carried out here using the EK280 keypad.
Parameterization can also be carried out using enSuite, where the below paths can be found under
"Parameterize
online" > "Parameter".
a) Setting automatic conversion:
On the EK280 display, move the cursor to tab "Serv." to:
Serv.
Volume
Press the ENTER ⇒ button. The set value flashes.
Repeatedly press one of the
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
b) Setting the high frequency pulse generator's input mode:
Press the
key, "Md.I2" is displayed.
Press the ENTER ⇒ button. The set value flashes.
Repeatedly press one of the
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
c) Setting the high frequency pulse generator's cp value:
Press the
key, "cp.I2" is displayed.
Press the ENTER ⇒ button. The set value flashes.
Move the cursor with the
to the cp value of the pulse generator connected to input 2.
Press the ENTER key to confirm the value setting. Input can be canceled using the ESC key.
d) Setting low frequency pulse generator parameters:
Set the parameters for the low frequency pulse generator on input 1 as described in chapter 4.1
(page 12).
Application Manual
Actual volume
Parameter settings
or
arrow keys until the text
or
arrow keys until the text
or ⊳ arrow keys to the digits and update them with the
Sc.Vm
"I2 or
I1" flashes.
"HF pulses
" flashes.
16