2.1

Performance specifications

The Table 1 describes performance specifications of the RTD module.
Item
Number of input
channels
Input sensor type
Temperature input
range
Digital output
Accuracy
Conversion speed
Isolation
Wiring method
Function
R200
Resistance Temperature Detector 2MLF-RD4A User's Guide
September 2010

2. Specifications

Table 1 – Performance specifications
4 channels
Pt100
JIS C1604-1997
JPt100
JIS C1604-1981, KS C1603-1991
Pt100
-200.0 – 850.0
JPt100
-200.0 – 640.0
PT100
Temperature display
(unit: 0.1)
JPT100
0 – 65535
Scaling display
(Customize)
-32768 – 32768
Normal temp. (25℃ )
Full temp. (0 – 55℃ )
Within ±0.3%
40ms / channel
Channel to Channel
Non-isolation
Photo-coupler
Terminal to PLC
Power
3-wire
Time average (320 – 64000ms)
Average
Counting average (2 – 64000 count)
Moving average (2 – 100 samples)
Alarm
Process alarm
Honeywell
Specifications
-200.0 – 850.0℃ /-328.0 – 1562.0℉
-200.0 – 640.0℃ /-328.0 – 1184.0℉
Within ±0.2%