THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
When the user presses the alert for more info, the Notification
screen is displayed, prompting them to contact their dealer.
See Fig. 185 as an example.
The following dry contact alerts are available.

Full Drain Pan Alert

When the dry contact device detects that the condensate drain
pan is full, the thermostat provides an alert to the user.
NOTE: If you want the compressor to turn off when the
drain pan is full, wire the system so the dry con-
tact device turns off the compressor when the
drain pan is full.
Dirty Filter Alert
When the dry contact device detects a dirty air filter (pressure
drop across the filter), the thermostat provides an alert to the
user to replace the filter.
Water Leak Alert
When the dry contact device detects a water leak, the
thermostat provides an alert to the user.
System Shutdown Alert
When the dry contact device detects a critical problem with the
system, the thermostat provides an alert to the user indicating
that the system was shut down.
MULTIPLE DRY CONTACT DEVICES
ON ONE SET OF TERMINALS
68-0311—02
Fig. 185.
ONE DRY CONTACT DEVICE
S4
S4
S3
S3
Fig. 186. Wiring dry contact devices.
®
IAQ WITH EIM
When the dry contact device detects a problem with the
system (for example, smoke detection), the thermostat will not
call for heating, cooling, fan or IAQ equipment until the dry
contact is deactivated or the feature is unconfigured at the
thermostat.

Service Needed Alert

When the dry contact device detects an issue that requires
service, the thermostat provides an alert to the user.

Fan Failure Alert

The Fan Failure Alert protects the equipment when there is no
airflow. When the dry contact device (for example, sail switch)
detects no air flow for 5 minutes after a call for forced air heat,
cool, or fan, the thermostat provides an alert to the user
indicating that the system was shut down due to a lack of
airflow.
The thermostat will call for the fan and lockout all other
equipment until the dry contact device senses air flow again or
the feature is unconfigured at the thermostat.

Custom Alert

Allows the dealer to enter a custom alert to be displayed when
a dry contact device is activated. For example, a float switch
can detect when your sump pump is not working.
Set Up the Dry Contact Alerts
WARNING
Equipment Damage Hazard.
Do not apply power to S1, S2, S3, or S4 terminals. Do
not connect a temperature sensor to the S1, S2, S3, or
S4 terminals if setup for a dry contact device.
IMPORTANT
The dry contact device must be rated for low voltage.
NOTE: You can connect multiple Dry Contact devices in
parallel to the S1, S2, S3, or S4 terminals.
You can connect the S1, S2, S3, or S4 terminals on the EIM to
a dry contact device to display an alert. Dry contact alerts
include Full Drain Pan, Dirty Filter, Water Leak, System
Shutdown, Service Needed, Fan Failure and Custom Alert. A
dry contact device can be normally open (shown in diagram) or
normally closed.
EIM
EIM
96
ONE DRY CONTACT DEVICE
MULTIPLE DRY CONTACT DEVICES
ON ONE SET OF TERMINALS