TrueSTEAM

1. Wire and power TrueSTEAM.
2. Connect the ABCD terminals between TrueSTEAM and
the THM4000 Wireless Adapter.
3. Adjust the DIP Switches on TrueSTEAM as follows when
using the Wireless Adapter:
• DIP3: UP
• DIP4: UP
• DIP5: DOWN
THM4000R1000
Fig. 26. Powering TrueSTEAM wireless adapter.

Entry/Exit Remote or Vent Boost Remote

1. Remove the cover.
2. Insert the CR2450 coin cell battery (included) into the
slot at the bottom of the remote. See polarity marking on
the remote.
Fig. 27. Installing Entry/Exit Remote or Vent Boost Remote
3. The LED will briefly flash green. If it flashes red, battery
is not good.
TrueSTEAM
1
2
3
4
5
ON
OFF
MCR31476
MCR33269
battery.
®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE

PERFORMING INITIAL SETUP

Initial setup options define the type of system you are installing:
• Residential or commercial
• Non-zoned or zoned
• Used with or without an Equipment Interface Module
(THM5421)
• Used with or without the TrueZONE Wireless Adapter
(THM4000)
1. Follow prompts on the screen to select the appropriate
options.
6
NOTE: If you are connecting the thermostat to the True-
ZONE Wireless Adapter (THM4000), refer to the
TrueZONE instructions to link the thermostat and
RedLINK accessories.
Linking Thermostat to Equipment
Interface Module (if used)
1. Press and quickly release the CONNECT button on the
EIM. Make sure the Connected light is flashing green.
Fig. 29. EIM CONNECT button.
NOTE: If the Connected light does NOT flash green,
another system may be in the listening mode.
Please exit the listening mode at the other system
and then try again.
• Green flashing: In Listening Mode. System is ready
to add RedLINK devices.
• Green steady: RedLINK devices are communicating.
• Red: RedLINK device(s) not communicating. Check
EIM and RedLINK devices.
15
®