Honeywell THX9321 Prestige 2.0 Product Data page 67

Hide thumbs Also See for THX9321 Prestige 2.0:
Table of Contents

Advertisement

ISU
Installer Setup
Number
Name
13170
Defrost Cycle
13180
Delta T Alert
Sensitivity
13190
Display Delta T
Alerts to User
14000
Clock Format
14010
Daylight Saving
Time
14020
Indoor
Temperature
Display Offset
14020
Indoor Humidity
Display Offset
15000
Dealer Name
15000
Dealer Phone
15010
Dealer Email
Address
15010
Dealer Website
15020
Dealer Message
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
None
1 to 60 minutes (in 1 minute
increments)
1 to 5
No
Yes
12 hour
24 hour
Off
On
-3° F to 3° F (in 1° F increments)
-12% to 12% (in 1% increments)
[Dealer Name]
[Dealer Phone]
[Dealer Email Address]
[Dealer Website]
[Dealer Message]
®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
Residential,
Commercial
Default
or Both
10
Both
3
Both
Yes
Both
12
Both
On
Both
0° F
Both
0%
Both
None
Both
None
Both
None
Both
None
Both
None
Both
67
Requires
EIM
Notes
Yes
This ISU is only displayed if ISU 2010
Heating Equipment Type is Air to Air Heat
Pump.
Press the up/down arrows to set the
maximum time duration of a defrost cycle.
Check the heat pump documentation for
the defrost cycle time.
Note: The diagnostic algorithm detects
when the system goes into defrost based
on the measured Delta T of the system.
When the thermostat detects this change in
temperature, the thermostat will not
compare Delta T to the Minimum and
Maximum Delta T Fault Limits. After the
defrost cycle has ended, the thermostat will
resume monitoring Delta T of the system.
Yes
See "Delta T Alert Sensitivity (ISU 13180)."
beginning on page 90.
Yes
No: The thermostat does NOT display a
Delta T alert to the user when a Delta T alert
is entered into the log.
Yes: The thermostat displays a Delta T alert
to the user when a Delta T alert is entered
into the log.
See "Delta T Alerts" beginning on page 90.
No
No
Set to Off in areas that do not follow
Daylight Saving Time.
No
0° F - No difference in displayed
temperature and the actual room
temperature.
The thermostat displays up to 3°F (1.5°C)
lower or higher than the actual measured
temperature.
No
0% - No difference in displayed humidity
and the actual room humidity.
The thermostat displays up to 12% lower
or higher than the actual measured
humidity.
No
No
No
No
No
®
IAQ WITH EIM
68-0311—02

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Thx9421 prestige iaq with eim

Table of Contents