Honeywell THX9321 Prestige 2.0 Product Data page 50

Hide thumbs Also See for THX9321 Prestige 2.0:
Table of Contents

Advertisement

®
THX9321 PRESTIGE
2.0 AND THX9421 PRESTIGE
ISU
Installer Setup
Number
Name
6000
Select the Dry
Contacts in the
System
6010
What Terminals are
Wired to the
Remote Setback
Dry Contact?
6020
Remote Setback
Dry Contact Setup
6030
Remote Setback
Time Delay from
Occupied to
Unoccupied
6040
Remote Setback -
Standby Cool
Setpoint
68-0311—02
Table 4. Installer Setup (ISU) Table. (Continued)
Settings
Check box on screen for each:
Remote Setback
Full Drain Pan Alert
Dirty Filter Alert
Water Leak Alert
System Shutdown Alert
Service Needed Alert
Fan Failure Alert
Custom Alert
None
S1
S2
S3
S4
Normally Open when Occupied
Normally Closed when Occupied
0 to 30 minutes (in 5 minute
increments)
72° F to 90° F
®
IAQ WITH EIM
Residential,
Commercial
Default
or Both
None
Both
Remote
Setback
(Commercial
Only)
None
Commercial
Normally Open
Commercial
when Occupied
0 minutes
Commercial
85° F
Commercial
50
Requires
EIM
Notes
Yes
Remote Setback and Dry Contact Alerts
requires an EIM (Equipment Interface
Module). This ISU is only displayed if one
of the S1-S4 terminals are available.
See "Dry Contact Alerts" beginning on
page 95.
Yes
Remote Setback requires an EIM
(Equipment Interface Module).
Yes
Remote Setback requires an EIM
(Equipment Interface Module).
Choose an option appropriate for the type
of device installed:
Normally Open when Occupied: The Dry
Contact device is open when the room is
occupied and will close when the room is
unoccupied.
Normally Closed when Occupied: The Dry
Contact device is closed when the room is
occupied and will open when the room is
unoccupied.
Yes
Remote Setback requires an EIM
(Equipment Interface Module).
The Remote Setback Time Delay forces
the thermostat to wait before it switches
from Occupied to Standby temperature
settings.
When set to 0 minutes, the thermostat will
switch from Occupied to Standby
temperature settings immediately when the
room is unoccupied.
Yes
Remote Setback requires an EIM
(Equipment Interface Module).
During occupied periods, the occupancy
sensor tells the thermostat to go to
STANDBY (setback settings) when no one
is in the room. If someone is in the room,
then it follows the settings of the occupied
period. The occupancy sensor is ignored
during unoccupied periods.
If the thermostat is setup for non-
programmable, the occupancy sensor tells
the thermostat to go to STANDBY settings
when no one is in the room. If someone is
in the room, then it follows the settings set
by the user.